Dionex Acclaim Organic Acid LC Column 液相色谱柱


Dionex Acclaim Organic Acid LC Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。

型号 美国戴安 P/N: 069580

Acclaim Organic Acid LC Column

Optimized and Application-Tested for the Analysis of Hydrophilic Organic Acids

The Acclaim? OA column offers unparalleled separations of hydrophilic aliphatic and aromatic organic acids using 100% aqueous phase and at low pH, using UV detection. The Acclaim OA column line features a patented polar-embedded stationary phase that is optimized and use-tested for hydroxyl aliphatic organic acid separations.

  • Use-tested to guarantee consistent hydrophilic organic acid separations
  • Compatible with 100% aqueous phases, optimum for hydrophilic organic acid retention
  • Hydrolytic stability at low-pH conditions, optimum for reversed-phase retention of organic acids
  • Ideal selectivity for separating a wide spectrum of organic acids
  • Excellent peak shapes for organic acids

The Acclaim OA organic acid columns can be operated at low pH and at 100% aqueous phases, conditions ideal for retaining and separating a wide spectrum of organic acids. Acclaim OA columns undergo extensive testing to ensure column-to-column reproducibility, and are shipped with certificates of analysis detailing these tests. The Acclaim OA columns are packed in metal-free PEEK? column bodies, to eliminate unwanted interaction between the analytes and the column body.

Acclaim OA is the recommended column for determining small hydrophilic organic acids, C1 to C7 aliphatic acids, and hydrophilic aromatic acid and is also valuable for the analysis and quality assurance of food and beverage products, pharmaceutical preparations, plating baths, and manufacturing chemicals and chemical intermediates.

Acclaim OA Column Applications

Applications include analysis of foods, beverages, pharmaceuticals, chemical intermediates and environmental samples. For example: aliphatic organic acids in foods (juice, wine, drinks), organic acids in drug preparations, acrylic acid and its oligomers, hydroxybenzoic acids, hydroxyphenylacetic acids, arylacetic acids, benzenpolycarboxylic acids and selected amino acids.

技术参数:

Acclaim OA Silica-Based Columns for the Separation of Organic Acids  Specifications
Particle size 3?m and 5 ?m
Particle shape Spherical
Particle size distribution (40/90) <1.3
Total carbon content 17%
Surface coverage 2.7 mmol/m2
End-capped Yes
Metal impurity (ppm), Na, Fe, Al <10.0 ppm Total Metal
<3.0 ppm Individual Metal
Pore volume 1.0 mL/g
Average pore diameter 120 ?
Surface area 300 m2/g
pH range 2–8
Temperature <60 °C
Starting material Ultrapure silica

订购信息:

Analytical Columns
Acclaim OA, 3?m Analytical, (3.0 x 150mm) 070086
Acclaim OA, 3?m Analytical, (2.1 x 150mm) 070087
Acclaim OA, 5 ?m Analytical (4 x 250 mm) 062902
Acclaim OA, 5 ?m Analytical (4 x 150 mm) 062903
Guard Columns
Acclaim OA, 5 ?m Guard Cartridge (4.6 x 10 mm), 2 ea (use V-2 Holder) 069700
Acclaim OA, 5?m Guard Cartridges (3 x 10mm), 2ea, requires holder 069580 071987
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188

Dionex Acclaim Organic Acid LC Column 液相色谱柱


Dionex Acclaim Organic Acid LC Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。

型号 美国戴安 P/N: 071987

Acclaim Organic Acid LC Column

Optimized and Application-Tested for the Analysis of Hydrophilic Organic Acids

The Acclaim? OA column offers unparalleled separations of hydrophilic aliphatic and aromatic organic acids using 100% aqueous phase and at low pH, using UV detection. The Acclaim OA column line features a patented polar-embedded stationary phase that is optimized and use-tested for hydroxyl aliphatic organic acid separations.

  • Use-tested to guarantee consistent hydrophilic organic acid separations
  • Compatible with 100% aqueous phases, optimum for hydrophilic organic acid retention
  • Hydrolytic stability at low-pH conditions, optimum for reversed-phase retention of organic acids
  • Ideal selectivity for separating a wide spectrum of organic acids
  • Excellent peak shapes for organic acids

The Acclaim OA organic acid columns can be operated at low pH and at 100% aqueous phases, conditions ideal for retaining and separating a wide spectrum of organic acids. Acclaim OA columns undergo extensive testing to ensure column-to-column reproducibility, and are shipped with certificates of analysis detailing these tests. The Acclaim OA columns are packed in metal-free PEEK? column bodies, to eliminate unwanted interaction between the analytes and the column body.

Acclaim OA is the recommended column for determining small hydrophilic organic acids, C1 to C7 aliphatic acids, and hydrophilic aromatic acid and is also valuable for the analysis and quality assurance of food and beverage products, pharmaceutical preparations, plating baths, and manufacturing chemicals and chemical intermediates.

Acclaim OA Column Applications

Applications include analysis of foods, beverages, pharmaceuticals, chemical intermediates and environmental samples. For example: aliphatic organic acids in foods (juice, wine, drinks), organic acids in drug preparations, acrylic acid and its oligomers, hydroxybenzoic acids, hydroxyphenylacetic acids, arylacetic acids, benzenpolycarboxylic acids and selected amino acids.

技术参数:

Acclaim OA Silica-Based Columns for the Separation of Organic Acids  Specifications
Particle size 3?m and 5 ?m
Particle shape Spherical
Particle size distribution (40/90) <1.3
Total carbon content 17%
Surface coverage 2.7 mmol/m2
End-capped Yes
Metal impurity (ppm), Na, Fe, Al <10.0 ppm Total Metal
<3.0 ppm Individual Metal
Pore volume 1.0 mL/g
Average pore diameter 120 ?
Surface area 300 m2/g
pH range 2–8
Temperature <60 °C
Starting material Ultrapure silica

订购信息:

Analytical Columns
Acclaim OA, 3?m Analytical, (3.0 x 150mm) 070086
Acclaim OA, 3?m Analytical, (2.1 x 150mm) 070087
Acclaim OA, 5 ?m Analytical (4 x 250 mm) 062902
Acclaim OA, 5 ?m Analytical (4 x 150 mm) 062903
Guard Columns
Acclaim OA, 5 ?m Guard Cartridge (4.6 x 10 mm), 2 ea (use V-2 Holder) 069700
Acclaim OA, 5?m Guard Cartridges (3 x 10mm), 2ea, requires holder 069580 071987
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188

Dionex Acclaim Organic Acid LC Column 液相色谱柱


Dionex Acclaim Organic Acid LC Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。

型号 美国戴安 P/N: 069700

Acclaim Organic Acid LC Column

Optimized and Application-Tested for the Analysis of Hydrophilic Organic Acids

The Acclaim? OA column offers unparalleled separations of hydrophilic aliphatic and aromatic organic acids using 100% aqueous phase and at low pH, using UV detection. The Acclaim OA column line features a patented polar-embedded stationary phase that is optimized and use-tested for hydroxyl aliphatic organic acid separations.

  • Use-tested to guarantee consistent hydrophilic organic acid separations
  • Compatible with 100% aqueous phases, optimum for hydrophilic organic acid retention
  • Hydrolytic stability at low-pH conditions, optimum for reversed-phase retention of organic acids
  • Ideal selectivity for separating a wide spectrum of organic acids
  • Excellent peak shapes for organic acids

The Acclaim OA organic acid columns can be operated at low pH and at 100% aqueous phases, conditions ideal for retaining and separating a wide spectrum of organic acids. Acclaim OA columns undergo extensive testing to ensure column-to-column reproducibility, and are shipped with certificates of analysis detailing these tests. The Acclaim OA columns are packed in metal-free PEEK? column bodies, to eliminate unwanted interaction between the analytes and the column body.

Acclaim OA is the recommended column for determining small hydrophilic organic acids, C1 to C7 aliphatic acids, and hydrophilic aromatic acid and is also valuable for the analysis and quality assurance of food and beverage products, pharmaceutical preparations, plating baths, and manufacturing chemicals and chemical intermediates.

Acclaim OA Column Applications

Applications include analysis of foods, beverages, pharmaceuticals, chemical intermediates and environmental samples. For example: aliphatic organic acids in foods (juice, wine, drinks), organic acids in drug preparations, acrylic acid and its oligomers, hydroxybenzoic acids, hydroxyphenylacetic acids, arylacetic acids, benzenpolycarboxylic acids and selected amino acids.

技术参数:

Acclaim OA Silica-Based Columns for the Separation of Organic Acids  Specifications
Particle size 3?m and 5 ?m
Particle shape Spherical
Particle size distribution (40/90) <1.3
Total carbon content 17%
Surface coverage 2.7 mmol/m2
End-capped Yes
Metal impurity (ppm), Na, Fe, Al <10.0 ppm Total Metal
<3.0 ppm Individual Metal
Pore volume 1.0 mL/g
Average pore diameter 120 ?
Surface area 300 m2/g
pH range 2–8
Temperature <60 °C
Starting material Ultrapure silica

订购信息:

Analytical Columns
Acclaim OA, 3?m Analytical, (3.0 x 150mm) 070086
Acclaim OA, 3?m Analytical, (2.1 x 150mm) 070087
Acclaim OA, 5 ?m Analytical (4 x 250 mm) 062902
Acclaim OA, 5 ?m Analytical (4 x 150 mm) 062903
Guard Columns
Acclaim OA, 5 ?m Guard Cartridge (4.6 x 10 mm), 2 ea (use V-2 Holder) 069700
Acclaim OA, 5?m Guard Cartridges (3 x 10mm), 2ea, requires holder 069580 071987
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188

Dionex Acclaim Organic Acid LC Column 液相色谱柱


Dionex Acclaim Organic Acid LC Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。

型号 美国戴安 P/N: 062903

Acclaim Organic Acid LC Column

Optimized and Application-Tested for the Analysis of Hydrophilic Organic Acids

The Acclaim? OA column offers unparalleled separations of hydrophilic aliphatic and aromatic organic acids using 100% aqueous phase and at low pH, using UV detection. The Acclaim OA column line features a patented polar-embedded stationary phase that is optimized and use-tested for hydroxyl aliphatic organic acid separations.

  • Use-tested to guarantee consistent hydrophilic organic acid separations
  • Compatible with 100% aqueous phases, optimum for hydrophilic organic acid retention
  • Hydrolytic stability at low-pH conditions, optimum for reversed-phase retention of organic acids
  • Ideal selectivity for separating a wide spectrum of organic acids
  • Excellent peak shapes for organic acids

The Acclaim OA organic acid columns can be operated at low pH and at 100% aqueous phases, conditions ideal for retaining and separating a wide spectrum of organic acids. Acclaim OA columns undergo extensive testing to ensure column-to-column reproducibility, and are shipped with certificates of analysis detailing these tests. The Acclaim OA columns are packed in metal-free PEEK? column bodies, to eliminate unwanted interaction between the analytes and the column body.

Acclaim OA is the recommended column for determining small hydrophilic organic acids, C1 to C7 aliphatic acids, and hydrophilic aromatic acid and is also valuable for the analysis and quality assurance of food and beverage products, pharmaceutical preparations, plating baths, and manufacturing chemicals and chemical intermediates.

Acclaim OA Column Applications

Applications include analysis of foods, beverages, pharmaceuticals, chemical intermediates and environmental samples. For example: aliphatic organic acids in foods (juice, wine, drinks), organic acids in drug preparations, acrylic acid and its oligomers, hydroxybenzoic acids, hydroxyphenylacetic acids, arylacetic acids, benzenpolycarboxylic acids and selected amino acids.

技术参数:

Acclaim OA Silica-Based Columns for the Separation of Organic Acids  Specifications
Particle size 3?m and 5 ?m
Particle shape Spherical
Particle size distribution (40/90) <1.3
Total carbon content 17%
Surface coverage 2.7 mmol/m2
End-capped Yes
Metal impurity (ppm), Na, Fe, Al <10.0 ppm Total Metal
<3.0 ppm Individual Metal
Pore volume 1.0 mL/g
Average pore diameter 120 ?
Surface area 300 m2/g
pH range 2–8
Temperature <60 °C
Starting material Ultrapure silica

订购信息:

Analytical Columns
Acclaim OA, 3?m Analytical, (3.0 x 150mm) 070086
Acclaim OA, 3?m Analytical, (2.1 x 150mm) 070087
Acclaim OA, 5 ?m Analytical (4 x 250 mm) 062902
Acclaim OA, 5 ?m Analytical (4 x 150 mm) 062903
Guard Columns
Acclaim OA, 5 ?m Guard Cartridge (4.6 x 10 mm), 2 ea (use V-2 Holder) 069700
Acclaim OA, 5?m Guard Cartridges (3 x 10mm), 2ea, requires holder 069580 071987
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188

Dionex Acclaim Organic Acid LC Column 液相色谱柱


Dionex Acclaim Organic Acid LC Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。

型号 美国戴安 P/N: 062902

Acclaim Organic Acid LC Column

Optimized and Application-Tested for the Analysis of Hydrophilic Organic Acids

The Acclaim? OA column offers unparalleled separations of hydrophilic aliphatic and aromatic organic acids using 100% aqueous phase and at low pH, using UV detection. The Acclaim OA column line features a patented polar-embedded stationary phase that is optimized and use-tested for hydroxyl aliphatic organic acid separations.

  • Use-tested to guarantee consistent hydrophilic organic acid separations
  • Compatible with 100% aqueous phases, optimum for hydrophilic organic acid retention
  • Hydrolytic stability at low-pH conditions, optimum for reversed-phase retention of organic acids
  • Ideal selectivity for separating a wide spectrum of organic acids
  • Excellent peak shapes for organic acids

The Acclaim OA organic acid columns can be operated at low pH and at 100% aqueous phases, conditions ideal for retaining and separating a wide spectrum of organic acids. Acclaim OA columns undergo extensive testing to ensure column-to-column reproducibility, and are shipped with certificates of analysis detailing these tests. The Acclaim OA columns are packed in metal-free PEEK? column bodies, to eliminate unwanted interaction between the analytes and the column body.

Acclaim OA is the recommended column for determining small hydrophilic organic acids, C1 to C7 aliphatic acids, and hydrophilic aromatic acid and is also valuable for the analysis and quality assurance of food and beverage products, pharmaceutical preparations, plating baths, and manufacturing chemicals and chemical intermediates.

Acclaim OA Column Applications

Applications include analysis of foods, beverages, pharmaceuticals, chemical intermediates and environmental samples. For example: aliphatic organic acids in foods (juice, wine, drinks), organic acids in drug preparations, acrylic acid and its oligomers, hydroxybenzoic acids, hydroxyphenylacetic acids, arylacetic acids, benzenpolycarboxylic acids and selected amino acids.

技术参数:

Acclaim OA Silica-Based Columns for the Separation of Organic Acids  Specifications
Particle size 3?m and 5 ?m
Particle shape Spherical
Particle size distribution (40/90) <1.3
Total carbon content 17%
Surface coverage 2.7 mmol/m2
End-capped Yes
Metal impurity (ppm), Na, Fe, Al <10.0 ppm Total Metal
<3.0 ppm Individual Metal
Pore volume 1.0 mL/g
Average pore diameter 120 ?
Surface area 300 m2/g
pH range 2–8
Temperature <60 °C
Starting material Ultrapure silica

订购信息:

Analytical Columns
Acclaim OA, 3?m Analytical, (3.0 x 150mm) 070086
Acclaim OA, 3?m Analytical, (2.1 x 150mm) 070087
Acclaim OA, 5 ?m Analytical (4 x 250 mm) 062902
Acclaim OA, 5 ?m Analytical (4 x 150 mm) 062903
Guard Columns
Acclaim OA, 5 ?m Guard Cartridge (4.6 x 10 mm), 2 ea (use V-2 Holder) 069700
Acclaim OA, 5?m Guard Cartridges (3 x 10mm), 2ea, requires holder 069580 071987
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188

Dionex Acclaim Organic Acid LC Column 液相色谱柱


Dionex Acclaim Organic Acid LC Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。

型号 美国戴安 P/N: 070087

Acclaim Organic Acid LC Column

Optimized and Application-Tested for the Analysis of Hydrophilic Organic Acids

The Acclaim? OA column offers unparalleled separations of hydrophilic aliphatic and aromatic organic acids using 100% aqueous phase and at low pH, using UV detection. The Acclaim OA column line features a patented polar-embedded stationary phase that is optimized and use-tested for hydroxyl aliphatic organic acid separations.

  • Use-tested to guarantee consistent hydrophilic organic acid separations
  • Compatible with 100% aqueous phases, optimum for hydrophilic organic acid retention
  • Hydrolytic stability at low-pH conditions, optimum for reversed-phase retention of organic acids
  • Ideal selectivity for separating a wide spectrum of organic acids
  • Excellent peak shapes for organic acids

The Acclaim OA organic acid columns can be operated at low pH and at 100% aqueous phases, conditions ideal for retaining and separating a wide spectrum of organic acids. Acclaim OA columns undergo extensive testing to ensure column-to-column reproducibility, and are shipped with certificates of analysis detailing these tests. The Acclaim OA columns are packed in metal-free PEEK? column bodies, to eliminate unwanted interaction between the analytes and the column body.

Acclaim OA is the recommended column for determining small hydrophilic organic acids, C1 to C7 aliphatic acids, and hydrophilic aromatic acid and is also valuable for the analysis and quality assurance of food and beverage products, pharmaceutical preparations, plating baths, and manufacturing chemicals and chemical intermediates.

Acclaim OA Column Applications

Applications include analysis of foods, beverages, pharmaceuticals, chemical intermediates and environmental samples. For example: aliphatic organic acids in foods (juice, wine, drinks), organic acids in drug preparations, acrylic acid and its oligomers, hydroxybenzoic acids, hydroxyphenylacetic acids, arylacetic acids, benzenpolycarboxylic acids and selected amino acids.

技术参数:

Acclaim OA Silica-Based Columns for the Separation of Organic Acids  Specifications
Particle size 3?m and 5 ?m
Particle shape Spherical
Particle size distribution (40/90) <1.3
Total carbon content 17%
Surface coverage 2.7 mmol/m2
End-capped Yes
Metal impurity (ppm), Na, Fe, Al <10.0 ppm Total Metal
<3.0 ppm Individual Metal
Pore volume 1.0 mL/g
Average pore diameter 120 ?
Surface area 300 m2/g
pH range 2–8
Temperature <60 °C
Starting material Ultrapure silica

订购信息:

Analytical Columns
Acclaim OA, 3?m Analytical, (3.0 x 150mm) 070086
Acclaim OA, 3?m Analytical, (2.1 x 150mm) 070087
Acclaim OA, 5 ?m Analytical (4 x 250 mm) 062902
Acclaim OA, 5 ?m Analytical (4 x 150 mm) 062903
Guard Columns
Acclaim OA, 5 ?m Guard Cartridge (4.6 x 10 mm), 2 ea (use V-2 Holder) 069700
Acclaim OA, 5?m Guard Cartridges (3 x 10mm), 2ea, requires holder 069580 071987
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188

Dionex Acclaim Organic Acid LC Column 液相色谱柱


Dionex Acclaim Organic Acid LC Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。

型号 美国戴安 P/N: 070086

Acclaim Organic Acid LC Column

Optimized and Application-Tested for the Analysis of Hydrophilic Organic Acids

The Acclaim? OA column offers unparalleled separations of hydrophilic aliphatic and aromatic organic acids using 100% aqueous phase and at low pH, using UV detection. The Acclaim OA column line features a patented polar-embedded stationary phase that is optimized and use-tested for hydroxyl aliphatic organic acid separations.

  • Use-tested to guarantee consistent hydrophilic organic acid separations
  • Compatible with 100% aqueous phases, optimum for hydrophilic organic acid retention
  • Hydrolytic stability at low-pH conditions, optimum for reversed-phase retention of organic acids
  • Ideal selectivity for separating a wide spectrum of organic acids
  • Excellent peak shapes for organic acids

The Acclaim OA organic acid columns can be operated at low pH and at 100% aqueous phases, conditions ideal for retaining and separating a wide spectrum of organic acids. Acclaim OA columns undergo extensive testing to ensure column-to-column reproducibility, and are shipped with certificates of analysis detailing these tests. The Acclaim OA columns are packed in metal-free PEEK? column bodies, to eliminate unwanted interaction between the analytes and the column body.

Acclaim OA is the recommended column for determining small hydrophilic organic acids, C1 to C7 aliphatic acids, and hydrophilic aromatic acid and is also valuable for the analysis and quality assurance of food and beverage products, pharmaceutical preparations, plating baths, and manufacturing chemicals and chemical intermediates.

Acclaim OA Column Applications

Applications include analysis of foods, beverages, pharmaceuticals, chemical intermediates and environmental samples. For example: aliphatic organic acids in foods (juice, wine, drinks), organic acids in drug preparations, acrylic acid and its oligomers, hydroxybenzoic acids, hydroxyphenylacetic acids, arylacetic acids, benzenpolycarboxylic acids and selected amino acids.

技术参数:

Acclaim OA Silica-Based Columns for the Separation of Organic Acids  Specifications
Particle size 3μm and 5 μm
Particle shape Spherical
Particle size distribution (40/90) <1.3
Total carbon content 17%
Surface coverage 2.7 mmol/m2
End-capped Yes
Metal impurity (ppm), Na, Fe, Al <10.0 ppm Total Metal
<3.0 ppm Individual Metal
Pore volume 1.0 mL/g
Average pore diameter 120 ?
Surface area 300 m2/g
pH range 2–8
Temperature <60 °C
Starting material Ultrapure silica

订购信息:

Analytical Columns
Acclaim OA, 3μm Analytical, (3.0 x 150mm) 070086
Acclaim OA, 3μm Analytical, (2.1 x 150mm) 070087
Acclaim OA, 5 μm Analytical (4 x 250 mm) 062902
Acclaim OA, 5 μm Analytical (4 x 150 mm) 062903
Guard Columns
Acclaim OA, 5 μm Guard Cartridge (4.6 x 10 mm), 2 ea (use V-2 Holder) 069700
Acclaim OA, 5μm Guard Cartridges (3 x 10mm), 2ea, requires holder 069580 071987
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188

Dionex Acclaim Carbamate LC Column 液相色谱柱


Dionex Acclaim Carbamate LC Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。

型号 美国戴安 P/N: 070086

Acclaim Carbamate LC Column 

The Acclaim Carbamate column is designed for baseline separation of carbamates (N-methylcarbamate and N-methylcarbamoyloxime pesticides) specified in US EPA Method 531.2. Carbamate pesticides are widely used throughout the world. Drinking water and raw surface water is monitored for the presence of carbamate pesticides and related compounds using an established EPA Method 531.2 that uses HPLC with postcolumn derivatization. LC-MS is the method of choice for the ultimate sensitivity.

  • Baseline separation of carbamate pesticides specified in US EPA Method 531.2
  • Use with either LC/postcolumn derivatization/fluorescence or LC/MS detection.
  • Compatible with both binary (methanol/water) and ternary (acetonitrile/methanol/water) phase gradients.
  • High efficiency, extremely low column bleed, and rugged column packing

Acclaim Carbamate columns are available in a variety of column formats: The 5 ?m, 4.6 × 250 mm column sets the standard for the highest resolution with postcolumn reaction (PCR) and fluorescence detection (FLD); the 3 ?m, 4.6 × 150 mm column saves time and increases sample throughput; the 3 ?m, 3.0 × 150 mm column saves time and reduces solvent consumption; and the 3 ?m, 2.1 × 150 mm column is for LC/MS, to achieve the lowest possible detection limits. Two RSLC, 2.2 ?m columns are available for high-resolution, high-throughput separations:  2.1 × 100 mm and 2.1 × 150 mm.

技术参数:

Acclaim Carbamate Column Specifications
Column chemistry Proprietary alkyl group
Operating pressure limit (recommended) 6000 psi (4000 psi)
Operating pH range (recommended) 2.5–8.0 (3.0–7.0)
Operating flow rate range (recommended) 0.5–3.0 (0.8–1.6) mL/min for 4.6 mm i.d. formats
0.3–1.5 (0.4–0.8) mL/min for 3.0 mm i.d. formats
0.15–0.80 (0.2–0.4) mL/min for 2.1 mm i.d. formats

订购信息:

Analytical Columns
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 150mm) 075596
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 100mm) 075597
Acclaim Carbamate, 5?m Analytical (4.6 x 250mm) 072924
Acclaim Carbamate, 3?m Analytical (4.6 x 150mm) 072925
Acclaim Carbamate, 3?m Analytical (3.0 x 150mm) 072926
Acclaim Carbamate, 3?m Analytical (2.1 x 150mm) 072927
Guard Columns
Acclaim Carbamate, 3?m Guard (4.6 x 10mm) 2ea (Use Holder V-2) 072928
Acclaim Carbamate, 3?m Guard (3.0 x 10mm) 2ea (Use Holder V-2) 072929
Acclaim Carbamate, 3?m Guard (2.1 x 10mm) 2ea (Use Holder V-2) 072930
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188

Dionex Acclaim Carbamate LC Column 液相色谱柱


Dionex Acclaim Carbamate LC Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。

型号 美国戴安 P/N: 074188

Acclaim Carbamate LC Column 

The Acclaim Carbamate column is designed for baseline separation of carbamates (N-methylcarbamate and N-methylcarbamoyloxime pesticides) specified in US EPA Method 531.2. Carbamate pesticides are widely used throughout the world. Drinking water and raw surface water is monitored for the presence of carbamate pesticides and related compounds using an established EPA Method 531.2 that uses HPLC with postcolumn derivatization. LC-MS is the method of choice for the ultimate sensitivity.

  • Baseline separation of carbamate pesticides specified in US EPA Method 531.2
  • Use with either LC/postcolumn derivatization/fluorescence or LC/MS detection.
  • Compatible with both binary (methanol/water) and ternary (acetonitrile/methanol/water) phase gradients.
  • High efficiency, extremely low column bleed, and rugged column packing

Acclaim Carbamate columns are available in a variety of column formats: The 5 ?m, 4.6 × 250 mm column sets the standard for the highest resolution with postcolumn reaction (PCR) and fluorescence detection (FLD); the 3 ?m, 4.6 × 150 mm column saves time and increases sample throughput; the 3 ?m, 3.0 × 150 mm column saves time and reduces solvent consumption; and the 3 ?m, 2.1 × 150 mm column is for LC/MS, to achieve the lowest possible detection limits. Two RSLC, 2.2 ?m columns are available for high-resolution, high-throughput separations:  2.1 × 100 mm and 2.1 × 150 mm.

技术参数:

Acclaim Carbamate Column Specifications
Column chemistry Proprietary alkyl group
Operating pressure limit (recommended) 6000 psi (4000 psi)
Operating pH range (recommended) 2.5–8.0 (3.0–7.0)
Operating flow rate range (recommended) 0.5–3.0 (0.8–1.6) mL/min for 4.6 mm i.d. formats
0.3–1.5 (0.4–0.8) mL/min for 3.0 mm i.d. formats
0.15–0.80 (0.2–0.4) mL/min for 2.1 mm i.d. formats

订购信息:

Analytical Columns
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 150mm) 075596
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 100mm) 075597
Acclaim Carbamate, 5?m Analytical (4.6 x 250mm) 072924
Acclaim Carbamate, 3?m Analytical (4.6 x 150mm) 072925
Acclaim Carbamate, 3?m Analytical (3.0 x 150mm) 072926
Acclaim Carbamate, 3?m Analytical (2.1 x 150mm) 072927
Guard Columns
Acclaim Carbamate, 3?m Guard (4.6 x 10mm) 2ea (Use Holder V-2) 072928
Acclaim Carbamate, 3?m Guard (3.0 x 10mm) 2ea (Use Holder V-2) 072929
Acclaim Carbamate, 3?m Guard (2.1 x 10mm) 2ea (Use Holder V-2) 072930
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188

Dionex Acclaim Carbamate LC Column 液相色谱柱


Dionex Acclaim Carbamate LC Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。

型号 美国戴安 P/N: 069707

Acclaim Carbamate LC Column 

The Acclaim Carbamate column is designed for baseline separation of carbamates (N-methylcarbamate and N-methylcarbamoyloxime pesticides) specified in US EPA Method 531.2. Carbamate pesticides are widely used throughout the world. Drinking water and raw surface water is monitored for the presence of carbamate pesticides and related compounds using an established EPA Method 531.2 that uses HPLC with postcolumn derivatization. LC-MS is the method of choice for the ultimate sensitivity.

  • Baseline separation of carbamate pesticides specified in US EPA Method 531.2
  • Use with either LC/postcolumn derivatization/fluorescence or LC/MS detection.
  • Compatible with both binary (methanol/water) and ternary (acetonitrile/methanol/water) phase gradients.
  • High efficiency, extremely low column bleed, and rugged column packing

Acclaim Carbamate columns are available in a variety of column formats: The 5 ?m, 4.6 × 250 mm column sets the standard for the highest resolution with postcolumn reaction (PCR) and fluorescence detection (FLD); the 3 ?m, 4.6 × 150 mm column saves time and increases sample throughput; the 3 ?m, 3.0 × 150 mm column saves time and reduces solvent consumption; and the 3 ?m, 2.1 × 150 mm column is for LC/MS, to achieve the lowest possible detection limits. Two RSLC, 2.2 ?m columns are available for high-resolution, high-throughput separations:  2.1 × 100 mm and 2.1 × 150 mm.

技术参数:

Acclaim Carbamate Column Specifications
Column chemistry Proprietary alkyl group
Operating pressure limit (recommended) 6000 psi (4000 psi)
Operating pH range (recommended) 2.5–8.0 (3.0–7.0)
Operating flow rate range (recommended) 0.5–3.0 (0.8–1.6) mL/min for 4.6 mm i.d. formats
0.3–1.5 (0.4–0.8) mL/min for 3.0 mm i.d. formats
0.15–0.80 (0.2–0.4) mL/min for 2.1 mm i.d. formats

订购信息:

Analytical Columns
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 150mm) 075596
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 100mm) 075597
Acclaim Carbamate, 5?m Analytical (4.6 x 250mm) 072924
Acclaim Carbamate, 3?m Analytical (4.6 x 150mm) 072925
Acclaim Carbamate, 3?m Analytical (3.0 x 150mm) 072926
Acclaim Carbamate, 3?m Analytical (2.1 x 150mm) 072927
Guard Columns
Acclaim Carbamate, 3?m Guard (4.6 x 10mm) 2ea (Use Holder V-2) 072928
Acclaim Carbamate, 3?m Guard (3.0 x 10mm) 2ea (Use Holder V-2) 072929
Acclaim Carbamate, 3?m Guard (2.1 x 10mm) 2ea (Use Holder V-2) 072930
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188

Dionex Acclaim Carbamate LC Column 液相色谱柱


Dionex Acclaim Carbamate LC Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。

型号 美国戴安 P/N: 069580

Acclaim Carbamate LC Column 

The Acclaim Carbamate column is designed for baseline separation of carbamates (N-methylcarbamate and N-methylcarbamoyloxime pesticides) specified in US EPA Method 531.2. Carbamate pesticides are widely used throughout the world. Drinking water and raw surface water is monitored for the presence of carbamate pesticides and related compounds using an established EPA Method 531.2 that uses HPLC with postcolumn derivatization. LC-MS is the method of choice for the ultimate sensitivity.

  • Baseline separation of carbamate pesticides specified in US EPA Method 531.2
  • Use with either LC/postcolumn derivatization/fluorescence or LC/MS detection.
  • Compatible with both binary (methanol/water) and ternary (acetonitrile/methanol/water) phase gradients.
  • High efficiency, extremely low column bleed, and rugged column packing

Acclaim Carbamate columns are available in a variety of column formats: The 5 ?m, 4.6 × 250 mm column sets the standard for the highest resolution with postcolumn reaction (PCR) and fluorescence detection (FLD); the 3 ?m, 4.6 × 150 mm column saves time and increases sample throughput; the 3 ?m, 3.0 × 150 mm column saves time and reduces solvent consumption; and the 3 ?m, 2.1 × 150 mm column is for LC/MS, to achieve the lowest possible detection limits. Two RSLC, 2.2 ?m columns are available for high-resolution, high-throughput separations:  2.1 × 100 mm and 2.1 × 150 mm.

技术参数:

Acclaim Carbamate Column Specifications
Column chemistry Proprietary alkyl group
Operating pressure limit (recommended) 6000 psi (4000 psi)
Operating pH range (recommended) 2.5–8.0 (3.0–7.0)
Operating flow rate range (recommended) 0.5–3.0 (0.8–1.6) mL/min for 4.6 mm i.d. formats
0.3–1.5 (0.4–0.8) mL/min for 3.0 mm i.d. formats
0.15–0.80 (0.2–0.4) mL/min for 2.1 mm i.d. formats

订购信息:

Analytical Columns
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 150mm) 075596
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 100mm) 075597
Acclaim Carbamate, 5?m Analytical (4.6 x 250mm) 072924
Acclaim Carbamate, 3?m Analytical (4.6 x 150mm) 072925
Acclaim Carbamate, 3?m Analytical (3.0 x 150mm) 072926
Acclaim Carbamate, 3?m Analytical (2.1 x 150mm) 072927
Guard Columns
Acclaim Carbamate, 3?m Guard (4.6 x 10mm) 2ea (Use Holder V-2) 072928
Acclaim Carbamate, 3?m Guard (3.0 x 10mm) 2ea (Use Holder V-2) 072929
Acclaim Carbamate, 3?m Guard (2.1 x 10mm) 2ea (Use Holder V-2) 072930
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188

Dionex Acclaim Carbamate LC Column 液相色谱柱


Dionex Acclaim Carbamate LC Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。

型号 美国戴安 P/N: 072930

Acclaim Carbamate LC Column 

The Acclaim Carbamate column is designed for baseline separation of carbamates (N-methylcarbamate and N-methylcarbamoyloxime pesticides) specified in US EPA Method 531.2. Carbamate pesticides are widely used throughout the world. Drinking water and raw surface water is monitored for the presence of carbamate pesticides and related compounds using an established EPA Method 531.2 that uses HPLC with postcolumn derivatization. LC-MS is the method of choice for the ultimate sensitivity.

  • Baseline separation of carbamate pesticides specified in US EPA Method 531.2
  • Use with either LC/postcolumn derivatization/fluorescence or LC/MS detection.
  • Compatible with both binary (methanol/water) and ternary (acetonitrile/methanol/water) phase gradients.
  • High efficiency, extremely low column bleed, and rugged column packing

Acclaim Carbamate columns are available in a variety of column formats: The 5 ?m, 4.6 × 250 mm column sets the standard for the highest resolution with postcolumn reaction (PCR) and fluorescence detection (FLD); the 3 ?m, 4.6 × 150 mm column saves time and increases sample throughput; the 3 ?m, 3.0 × 150 mm column saves time and reduces solvent consumption; and the 3 ?m, 2.1 × 150 mm column is for LC/MS, to achieve the lowest possible detection limits. Two RSLC, 2.2 ?m columns are available for high-resolution, high-throughput separations:  2.1 × 100 mm and 2.1 × 150 mm.

技术参数:

Acclaim Carbamate Column Specifications
Column chemistry Proprietary alkyl group
Operating pressure limit (recommended) 6000 psi (4000 psi)
Operating pH range (recommended) 2.5–8.0 (3.0–7.0)
Operating flow rate range (recommended) 0.5–3.0 (0.8–1.6) mL/min for 4.6 mm i.d. formats
0.3–1.5 (0.4–0.8) mL/min for 3.0 mm i.d. formats
0.15–0.80 (0.2–0.4) mL/min for 2.1 mm i.d. formats

订购信息:

Analytical Columns
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 150mm) 075596
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 100mm) 075597
Acclaim Carbamate, 5?m Analytical (4.6 x 250mm) 072924
Acclaim Carbamate, 3?m Analytical (4.6 x 150mm) 072925
Acclaim Carbamate, 3?m Analytical (3.0 x 150mm) 072926
Acclaim Carbamate, 3?m Analytical (2.1 x 150mm) 072927
Guard Columns
Acclaim Carbamate, 3?m Guard (4.6 x 10mm) 2ea (Use Holder V-2) 072928
Acclaim Carbamate, 3?m Guard (3.0 x 10mm) 2ea (Use Holder V-2) 072929
Acclaim Carbamate, 3?m Guard (2.1 x 10mm) 2ea (Use Holder V-2) 072930
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188

Dionex Acclaim Carbamate LC Column 液相色谱柱


Dionex Acclaim Carbamate LC Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。

型号 美国戴安 P/N: 072929

Acclaim Carbamate LC Column 

The Acclaim Carbamate column is designed for baseline separation of carbamates (N-methylcarbamate and N-methylcarbamoyloxime pesticides) specified in US EPA Method 531.2. Carbamate pesticides are widely used throughout the world. Drinking water and raw surface water is monitored for the presence of carbamate pesticides and related compounds using an established EPA Method 531.2 that uses HPLC with postcolumn derivatization. LC-MS is the method of choice for the ultimate sensitivity.

  • Baseline separation of carbamate pesticides specified in US EPA Method 531.2
  • Use with either LC/postcolumn derivatization/fluorescence or LC/MS detection.
  • Compatible with both binary (methanol/water) and ternary (acetonitrile/methanol/water) phase gradients.
  • High efficiency, extremely low column bleed, and rugged column packing

Acclaim Carbamate columns are available in a variety of column formats: The 5 ?m, 4.6 × 250 mm column sets the standard for the highest resolution with postcolumn reaction (PCR) and fluorescence detection (FLD); the 3 ?m, 4.6 × 150 mm column saves time and increases sample throughput; the 3 ?m, 3.0 × 150 mm column saves time and reduces solvent consumption; and the 3 ?m, 2.1 × 150 mm column is for LC/MS, to achieve the lowest possible detection limits. Two RSLC, 2.2 ?m columns are available for high-resolution, high-throughput separations:  2.1 × 100 mm and 2.1 × 150 mm.

技术参数:

Acclaim Carbamate Column Specifications
Column chemistry Proprietary alkyl group
Operating pressure limit (recommended) 6000 psi (4000 psi)
Operating pH range (recommended) 2.5–8.0 (3.0–7.0)
Operating flow rate range (recommended) 0.5–3.0 (0.8–1.6) mL/min for 4.6 mm i.d. formats
0.3–1.5 (0.4–0.8) mL/min for 3.0 mm i.d. formats
0.15–0.80 (0.2–0.4) mL/min for 2.1 mm i.d. formats

订购信息:

Analytical Columns
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 150mm) 075596
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 100mm) 075597
Acclaim Carbamate, 5?m Analytical (4.6 x 250mm) 072924
Acclaim Carbamate, 3?m Analytical (4.6 x 150mm) 072925
Acclaim Carbamate, 3?m Analytical (3.0 x 150mm) 072926
Acclaim Carbamate, 3?m Analytical (2.1 x 150mm) 072927
Guard Columns
Acclaim Carbamate, 3?m Guard (4.6 x 10mm) 2ea (Use Holder V-2) 072928
Acclaim Carbamate, 3?m Guard (3.0 x 10mm) 2ea (Use Holder V-2) 072929
Acclaim Carbamate, 3?m Guard (2.1 x 10mm) 2ea (Use Holder V-2) 072930
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188

Dionex Acclaim Carbamate LC Column 液相色谱柱


Dionex Acclaim Carbamate LC Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。

型号 美国戴安 P/N: 072928

Acclaim Carbamate LC Column 

The Acclaim Carbamate column is designed for baseline separation of carbamates (N-methylcarbamate and N-methylcarbamoyloxime pesticides) specified in US EPA Method 531.2. Carbamate pesticides are widely used throughout the world. Drinking water and raw surface water is monitored for the presence of carbamate pesticides and related compounds using an established EPA Method 531.2 that uses HPLC with postcolumn derivatization. LC-MS is the method of choice for the ultimate sensitivity.

  • Baseline separation of carbamate pesticides specified in US EPA Method 531.2
  • Use with either LC/postcolumn derivatization/fluorescence or LC/MS detection.
  • Compatible with both binary (methanol/water) and ternary (acetonitrile/methanol/water) phase gradients.
  • High efficiency, extremely low column bleed, and rugged column packing

Acclaim Carbamate columns are available in a variety of column formats: The 5 ?m, 4.6 × 250 mm column sets the standard for the highest resolution with postcolumn reaction (PCR) and fluorescence detection (FLD); the 3 ?m, 4.6 × 150 mm column saves time and increases sample throughput; the 3 ?m, 3.0 × 150 mm column saves time and reduces solvent consumption; and the 3 ?m, 2.1 × 150 mm column is for LC/MS, to achieve the lowest possible detection limits. Two RSLC, 2.2 ?m columns are available for high-resolution, high-throughput separations:  2.1 × 100 mm and 2.1 × 150 mm.

技术参数:

Acclaim Carbamate Column Specifications
Column chemistry Proprietary alkyl group
Operating pressure limit (recommended) 6000 psi (4000 psi)
Operating pH range (recommended) 2.5–8.0 (3.0–7.0)
Operating flow rate range (recommended) 0.5–3.0 (0.8–1.6) mL/min for 4.6 mm i.d. formats
0.3–1.5 (0.4–0.8) mL/min for 3.0 mm i.d. formats
0.15–0.80 (0.2–0.4) mL/min for 2.1 mm i.d. formats

订购信息:

Analytical Columns
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 150mm) 075596
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 100mm) 075597
Acclaim Carbamate, 5?m Analytical (4.6 x 250mm) 072924
Acclaim Carbamate, 3?m Analytical (4.6 x 150mm) 072925
Acclaim Carbamate, 3?m Analytical (3.0 x 150mm) 072926
Acclaim Carbamate, 3?m Analytical (2.1 x 150mm) 072927
Guard Columns
Acclaim Carbamate, 3?m Guard (4.6 x 10mm) 2ea (Use Holder V-2) 072928
Acclaim Carbamate, 3?m Guard (3.0 x 10mm) 2ea (Use Holder V-2) 072929
Acclaim Carbamate, 3?m Guard (2.1 x 10mm) 2ea (Use Holder V-2) 072930
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188

Dionex Acclaim Carbamate LC Column 液相色谱柱


Dionex Acclaim Carbamate LC Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。

型号 美国戴安 P/N: 072927

Acclaim Carbamate LC Column 

The Acclaim Carbamate column is designed for baseline separation of carbamates (N-methylcarbamate and N-methylcarbamoyloxime pesticides) specified in US EPA Method 531.2. Carbamate pesticides are widely used throughout the world. Drinking water and raw surface water is monitored for the presence of carbamate pesticides and related compounds using an established EPA Method 531.2 that uses HPLC with postcolumn derivatization. LC-MS is the method of choice for the ultimate sensitivity.

  • Baseline separation of carbamate pesticides specified in US EPA Method 531.2
  • Use with either LC/postcolumn derivatization/fluorescence or LC/MS detection.
  • Compatible with both binary (methanol/water) and ternary (acetonitrile/methanol/water) phase gradients.
  • High efficiency, extremely low column bleed, and rugged column packing

Acclaim Carbamate columns are available in a variety of column formats: The 5 ?m, 4.6 × 250 mm column sets the standard for the highest resolution with postcolumn reaction (PCR) and fluorescence detection (FLD); the 3 ?m, 4.6 × 150 mm column saves time and increases sample throughput; the 3 ?m, 3.0 × 150 mm column saves time and reduces solvent consumption; and the 3 ?m, 2.1 × 150 mm column is for LC/MS, to achieve the lowest possible detection limits. Two RSLC, 2.2 ?m columns are available for high-resolution, high-throughput separations:  2.1 × 100 mm and 2.1 × 150 mm.

技术参数:

Acclaim Carbamate Column Specifications
Column chemistry Proprietary alkyl group
Operating pressure limit (recommended) 6000 psi (4000 psi)
Operating pH range (recommended) 2.5–8.0 (3.0–7.0)
Operating flow rate range (recommended) 0.5–3.0 (0.8–1.6) mL/min for 4.6 mm i.d. formats
0.3–1.5 (0.4–0.8) mL/min for 3.0 mm i.d. formats
0.15–0.80 (0.2–0.4) mL/min for 2.1 mm i.d. formats

订购信息:

Analytical Columns
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 150mm) 075596
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 100mm) 075597
Acclaim Carbamate, 5?m Analytical (4.6 x 250mm) 072924
Acclaim Carbamate, 3?m Analytical (4.6 x 150mm) 072925
Acclaim Carbamate, 3?m Analytical (3.0 x 150mm) 072926
Acclaim Carbamate, 3?m Analytical (2.1 x 150mm) 072927
Guard Columns
Acclaim Carbamate, 3?m Guard (4.6 x 10mm) 2ea (Use Holder V-2) 072928
Acclaim Carbamate, 3?m Guard (3.0 x 10mm) 2ea (Use Holder V-2) 072929
Acclaim Carbamate, 3?m Guard (2.1 x 10mm) 2ea (Use Holder V-2) 072930
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188

Dionex Acclaim Carbamate LC Column 液相色谱柱


Dionex Acclaim Carbamate LC Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。

型号 美国戴安 P/N: 072926

Acclaim Carbamate LC Column 

The Acclaim Carbamate column is designed for baseline separation of carbamates (N-methylcarbamate and N-methylcarbamoyloxime pesticides) specified in US EPA Method 531.2. Carbamate pesticides are widely used throughout the world. Drinking water and raw surface water is monitored for the presence of carbamate pesticides and related compounds using an established EPA Method 531.2 that uses HPLC with postcolumn derivatization. LC-MS is the method of choice for the ultimate sensitivity.

  • Baseline separation of carbamate pesticides specified in US EPA Method 531.2
  • Use with either LC/postcolumn derivatization/fluorescence or LC/MS detection.
  • Compatible with both binary (methanol/water) and ternary (acetonitrile/methanol/water) phase gradients.
  • High efficiency, extremely low column bleed, and rugged column packing

Acclaim Carbamate columns are available in a variety of column formats: The 5 ?m, 4.6 × 250 mm column sets the standard for the highest resolution with postcolumn reaction (PCR) and fluorescence detection (FLD); the 3 ?m, 4.6 × 150 mm column saves time and increases sample throughput; the 3 ?m, 3.0 × 150 mm column saves time and reduces solvent consumption; and the 3 ?m, 2.1 × 150 mm column is for LC/MS, to achieve the lowest possible detection limits. Two RSLC, 2.2 ?m columns are available for high-resolution, high-throughput separations:  2.1 × 100 mm and 2.1 × 150 mm.

技术参数:

Acclaim Carbamate Column Specifications
Column chemistry Proprietary alkyl group
Operating pressure limit (recommended) 6000 psi (4000 psi)
Operating pH range (recommended) 2.5–8.0 (3.0–7.0)
Operating flow rate range (recommended) 0.5–3.0 (0.8–1.6) mL/min for 4.6 mm i.d. formats
0.3–1.5 (0.4–0.8) mL/min for 3.0 mm i.d. formats
0.15–0.80 (0.2–0.4) mL/min for 2.1 mm i.d. formats

订购信息:

Analytical Columns
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 150mm) 075596
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 100mm) 075597
Acclaim Carbamate, 5?m Analytical (4.6 x 250mm) 072924
Acclaim Carbamate, 3?m Analytical (4.6 x 150mm) 072925
Acclaim Carbamate, 3?m Analytical (3.0 x 150mm) 072926
Acclaim Carbamate, 3?m Analytical (2.1 x 150mm) 072927
Guard Columns
Acclaim Carbamate, 3?m Guard (4.6 x 10mm) 2ea (Use Holder V-2) 072928
Acclaim Carbamate, 3?m Guard (3.0 x 10mm) 2ea (Use Holder V-2) 072929
Acclaim Carbamate, 3?m Guard (2.1 x 10mm) 2ea (Use Holder V-2) 072930
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188

Dionex Acclaim Carbamate LC Column 液相色谱柱


Dionex Acclaim Carbamate LC Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。

型号 美国戴安 P/N: 072925

Acclaim Carbamate LC Column 

The Acclaim Carbamate column is designed for baseline separation of carbamates (N-methylcarbamate and N-methylcarbamoyloxime pesticides) specified in US EPA Method 531.2. Carbamate pesticides are widely used throughout the world. Drinking water and raw surface water is monitored for the presence of carbamate pesticides and related compounds using an established EPA Method 531.2 that uses HPLC with postcolumn derivatization. LC-MS is the method of choice for the ultimate sensitivity.

  • Baseline separation of carbamate pesticides specified in US EPA Method 531.2
  • Use with either LC/postcolumn derivatization/fluorescence or LC/MS detection.
  • Compatible with both binary (methanol/water) and ternary (acetonitrile/methanol/water) phase gradients.
  • High efficiency, extremely low column bleed, and rugged column packing

Acclaim Carbamate columns are available in a variety of column formats: The 5 ?m, 4.6 × 250 mm column sets the standard for the highest resolution with postcolumn reaction (PCR) and fluorescence detection (FLD); the 3 ?m, 4.6 × 150 mm column saves time and increases sample throughput; the 3 ?m, 3.0 × 150 mm column saves time and reduces solvent consumption; and the 3 ?m, 2.1 × 150 mm column is for LC/MS, to achieve the lowest possible detection limits. Two RSLC, 2.2 ?m columns are available for high-resolution, high-throughput separations:  2.1 × 100 mm and 2.1 × 150 mm.

技术参数:

Acclaim Carbamate Column Specifications
Column chemistry Proprietary alkyl group
Operating pressure limit (recommended) 6000 psi (4000 psi)
Operating pH range (recommended) 2.5–8.0 (3.0–7.0)
Operating flow rate range (recommended) 0.5–3.0 (0.8–1.6) mL/min for 4.6 mm i.d. formats
0.3–1.5 (0.4–0.8) mL/min for 3.0 mm i.d. formats
0.15–0.80 (0.2–0.4) mL/min for 2.1 mm i.d. formats

订购信息:

Analytical Columns
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 150mm) 075596
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 100mm) 075597
Acclaim Carbamate, 5?m Analytical (4.6 x 250mm) 072924
Acclaim Carbamate, 3?m Analytical (4.6 x 150mm) 072925
Acclaim Carbamate, 3?m Analytical (3.0 x 150mm) 072926
Acclaim Carbamate, 3?m Analytical (2.1 x 150mm) 072927
Guard Columns
Acclaim Carbamate, 3?m Guard (4.6 x 10mm) 2ea (Use Holder V-2) 072928
Acclaim Carbamate, 3?m Guard (3.0 x 10mm) 2ea (Use Holder V-2) 072929
Acclaim Carbamate, 3?m Guard (2.1 x 10mm) 2ea (Use Holder V-2) 072930
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188

Dionex Acclaim Carbamate LC Column 液相色谱柱


Dionex Acclaim Carbamate LC Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。

型号 美国戴安 P/N: 072924

Acclaim Carbamate LC Column 

The Acclaim Carbamate column is designed for baseline separation of carbamates (N-methylcarbamate and N-methylcarbamoyloxime pesticides) specified in US EPA Method 531.2. Carbamate pesticides are widely used throughout the world. Drinking water and raw surface water is monitored for the presence of carbamate pesticides and related compounds using an established EPA Method 531.2 that uses HPLC with postcolumn derivatization. LC-MS is the method of choice for the ultimate sensitivity.

  • Baseline separation of carbamate pesticides specified in US EPA Method 531.2
  • Use with either LC/postcolumn derivatization/fluorescence or LC/MS detection.
  • Compatible with both binary (methanol/water) and ternary (acetonitrile/methanol/water) phase gradients.
  • High efficiency, extremely low column bleed, and rugged column packing

Acclaim Carbamate columns are available in a variety of column formats: The 5 ?m, 4.6 × 250 mm column sets the standard for the highest resolution with postcolumn reaction (PCR) and fluorescence detection (FLD); the 3 ?m, 4.6 × 150 mm column saves time and increases sample throughput; the 3 ?m, 3.0 × 150 mm column saves time and reduces solvent consumption; and the 3 ?m, 2.1 × 150 mm column is for LC/MS, to achieve the lowest possible detection limits. Two RSLC, 2.2 ?m columns are available for high-resolution, high-throughput separations:  2.1 × 100 mm and 2.1 × 150 mm.

技术参数:

Acclaim Carbamate Column Specifications
Column chemistry Proprietary alkyl group
Operating pressure limit (recommended) 6000 psi (4000 psi)
Operating pH range (recommended) 2.5–8.0 (3.0–7.0)
Operating flow rate range (recommended) 0.5–3.0 (0.8–1.6) mL/min for 4.6 mm i.d. formats
0.3–1.5 (0.4–0.8) mL/min for 3.0 mm i.d. formats
0.15–0.80 (0.2–0.4) mL/min for 2.1 mm i.d. formats

订购信息:

Analytical Columns
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 150mm) 075596
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 100mm) 075597
Acclaim Carbamate, 5?m Analytical (4.6 x 250mm) 072924
Acclaim Carbamate, 3?m Analytical (4.6 x 150mm) 072925
Acclaim Carbamate, 3?m Analytical (3.0 x 150mm) 072926
Acclaim Carbamate, 3?m Analytical (2.1 x 150mm) 072927
Guard Columns
Acclaim Carbamate, 3?m Guard (4.6 x 10mm) 2ea (Use Holder V-2) 072928
Acclaim Carbamate, 3?m Guard (3.0 x 10mm) 2ea (Use Holder V-2) 072929
Acclaim Carbamate, 3?m Guard (2.1 x 10mm) 2ea (Use Holder V-2) 072930
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188

Dionex Acclaim Carbamate LC Column 液相色谱柱


Dionex Acclaim Carbamate LC Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。

型号 美国戴安 P/N: 075597

Acclaim Carbamate LC Column 

The Acclaim Carbamate column is designed for baseline separation of carbamates (N-methylcarbamate and N-methylcarbamoyloxime pesticides) specified in US EPA Method 531.2. Carbamate pesticides are widely used throughout the world. Drinking water and raw surface water is monitored for the presence of carbamate pesticides and related compounds using an established EPA Method 531.2 that uses HPLC with postcolumn derivatization. LC-MS is the method of choice for the ultimate sensitivity.

  • Baseline separation of carbamate pesticides specified in US EPA Method 531.2
  • Use with either LC/postcolumn derivatization/fluorescence or LC/MS detection.
  • Compatible with both binary (methanol/water) and ternary (acetonitrile/methanol/water) phase gradients.
  • High efficiency, extremely low column bleed, and rugged column packing

Acclaim Carbamate columns are available in a variety of column formats: The 5 ?m, 4.6 × 250 mm column sets the standard for the highest resolution with postcolumn reaction (PCR) and fluorescence detection (FLD); the 3 ?m, 4.6 × 150 mm column saves time and increases sample throughput; the 3 ?m, 3.0 × 150 mm column saves time and reduces solvent consumption; and the 3 ?m, 2.1 × 150 mm column is for LC/MS, to achieve the lowest possible detection limits. Two RSLC, 2.2 ?m columns are available for high-resolution, high-throughput separations:  2.1 × 100 mm and 2.1 × 150 mm.

技术参数:

Acclaim Carbamate Column Specifications
Column chemistry Proprietary alkyl group
Operating pressure limit (recommended) 6000 psi (4000 psi)
Operating pH range (recommended) 2.5–8.0 (3.0–7.0)
Operating flow rate range (recommended) 0.5–3.0 (0.8–1.6) mL/min for 4.6 mm i.d. formats
0.3–1.5 (0.4–0.8) mL/min for 3.0 mm i.d. formats
0.15–0.80 (0.2–0.4) mL/min for 2.1 mm i.d. formats

订购信息:

Analytical Columns
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 150mm) 075596
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 100mm) 075597
Acclaim Carbamate, 5?m Analytical (4.6 x 250mm) 072924
Acclaim Carbamate, 3?m Analytical (4.6 x 150mm) 072925
Acclaim Carbamate, 3?m Analytical (3.0 x 150mm) 072926
Acclaim Carbamate, 3?m Analytical (2.1 x 150mm) 072927
Guard Columns
Acclaim Carbamate, 3?m Guard (4.6 x 10mm) 2ea (Use Holder V-2) 072928
Acclaim Carbamate, 3?m Guard (3.0 x 10mm) 2ea (Use Holder V-2) 072929
Acclaim Carbamate, 3?m Guard (2.1 x 10mm) 2ea (Use Holder V-2) 072930
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188

Dionex Acclaim Carbamate LC Column 液相色谱柱


Dionex Acclaim Carbamate LC Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。

型号 美国戴安 P/N: 075596

Acclaim Carbamate LC Column 

The Acclaim Carbamate column is designed for baseline separation of carbamates (N-methylcarbamate and N-methylcarbamoyloxime pesticides) specified in US EPA Method 531.2. Carbamate pesticides are widely used throughout the world. Drinking water and raw surface water is monitored for the presence of carbamate pesticides and related compounds using an established EPA Method 531.2 that uses HPLC with postcolumn derivatization. LC-MS is the method of choice for the ultimate sensitivity.

  • Baseline separation of carbamate pesticides specified in US EPA Method 531.2
  • Use with either LC/postcolumn derivatization/fluorescence or LC/MS detection.
  • Compatible with both binary (methanol/water) and ternary (acetonitrile/methanol/water) phase gradients.
  • High efficiency, extremely low column bleed, and rugged column packing

Acclaim Carbamate columns are available in a variety of column formats: The 5 ?m, 4.6 × 250 mm column sets the standard for the highest resolution with postcolumn reaction (PCR) and fluorescence detection (FLD); the 3 ?m, 4.6 × 150 mm column saves time and increases sample throughput; the 3 ?m, 3.0 × 150 mm column saves time and reduces solvent consumption; and the 3 ?m, 2.1 × 150 mm column is for LC/MS, to achieve the lowest possible detection limits. Two RSLC, 2.2 ?m columns are available for high-resolution, high-throughput separations:  2.1 × 100 mm and 2.1 × 150 mm.

技术参数:

Acclaim Carbamate Column Specifications
Column chemistry Proprietary alkyl group
Operating pressure limit (recommended) 6000 psi (4000 psi)
Operating pH range (recommended) 2.5–8.0 (3.0–7.0)
Operating flow rate range (recommended) 0.5–3.0 (0.8–1.6) mL/min for 4.6 mm i.d. formats
0.3–1.5 (0.4–0.8) mL/min for 3.0 mm i.d. formats
0.15–0.80 (0.2–0.4) mL/min for 2.1 mm i.d. formats

订购信息:

Analytical Columns
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 150mm) 075596
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 100mm) 075597
Acclaim Carbamate, 5?m Analytical (4.6 x 250mm) 072924
Acclaim Carbamate, 3?m Analytical (4.6 x 150mm) 072925
Acclaim Carbamate, 3?m Analytical (3.0 x 150mm) 072926
Acclaim Carbamate, 3?m Analytical (2.1 x 150mm) 072927
Guard Columns
Acclaim Carbamate, 3?m Guard (4.6 x 10mm) 2ea (Use Holder V-2) 072928
Acclaim Carbamate, 3?m Guard (3.0 x 10mm) 2ea (Use Holder V-2) 072929
Acclaim Carbamate, 3?m Guard (2.1 x 10mm) 2ea (Use Holder V-2) 072930
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188