Dionex IonPac AS11-HC Column 阴离子交换色谱柱


Dionex IonPac AS11-HC Column 阴离子交换色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。   
戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。

型号 美国戴安 P/N: 052961

Thermo Scientific Dionex IonPac AS11-HC Hydroxide-Selective Anion-Exchange Column

For Resolving a Large Number of Inorganic Anions and Organic Acid Anions in Complex Matrices

Complex sample matrices such as chemical wastewater effluents and fermentation broth solutions contain a variety of inorganic anions and organic acids. The Thermo Scientific* Dionex* IonPac* AS11-HC column was specifically designed to resolve a large number of inorganic anions and organic acid anions in a single run using a hydroxide gradient. The new Dionex IonPac AS11-HC Capillary Column is packed with the same material as the equivalent standard bore and microbore versions (providing the same performance as a 4 mm and 2 mm column) but requires only 1/100th the eluent flow rate. The capillary format provides the advantage of significantly reduced eluent consumption, which helps reduce operating costs

  • Use for organic acids and anions in complex sample matrices or uncharacterized samples.
  • Recommended for monovalent and divalent organic acids.
  • Use the Dionex Ionpac AS11 for fast analysis of organic acids and anions in well-characterized samples.
  • Use the Dionex IonPac ICE-AS1 or ICE-AS6 columns for organic acids in high-ionic-strength samples.
  • High capacity translates into longer retention times, but with higher resolution.

The high-capacity Dionex IonPac AS11-HC column allows the injection of more concentrated samples without column overloading or peak broadening, and provides improved separation over the Dionex IonPac AS11 column for monovalent carboxylic acids, including quinate, lactate, acetate, propionate, formate, and butyrate.

Dionex IonPac* AS11-HC Anion-Exchange Column Specifications
Dimensions Dionex IonPac AS11-HC Analytical Column:
2 × 250 mm and 4 × 250 mm
Dionex IonPac AG11-HC Guard Column:
2 × 50 mm and 4 × 50 mm
Dionex IonPac AS11-HC Capillary Column
0.4 × 250 mm
Dionex IonPac AS11-HC Capillary Guard Column
0.4 × 50 mm
Maximum operating pressure 4000 psi (27 MPa)
Mobil phase compatibility pH 0–14; 0–100% HPLC solvents
Substrate characteristics Bead Diameter: 9.0 ?m
Pore Size: 2000 ?
Cross-Linking (%DVB): 55%
Latex characteristics Functional Group: Alkanol quaternary ammonium ion
Latex Cross-Linking: 6%
Latex Diameter: 70 nm
Hydrophobicity: Medium low
Capacity 72.5 ?eq (2 × 250 mm analytical column)
290 ?eq (4 × 250 mm analytical column)
2.9 ?eq (0.4 × 250 mm capillary column)
Column construction PEEK? with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.

Analytical Columns
IonPac AS11-HC Analytical Column (4 x 250 mm) 052960
IonPac AS11-HC Analytical Column (2 x 250 mm) 052961
IonPac AS11-HC Capillary Column (0.4 x 250 mm) 078429
Guard Columns
IonPac AG11-HC Guard Column (4 x 50 mm) 052962
IonPac AG11-HC Guard Column (2 x 50 mm) 052963
IonPac AG11-HC Capillary Guard Column (0.4 x 50 mm) 078430