型号 美国戴安 P/N: 088236

Dionex CarboPac SA10-4?m Column 

for Fast, High-Resolution Mono- and Disaccharide Analysis

The New Thermo Scientific? Dionex? CarboPac? SA10-4?m Column is designed for fast chromatographic analysis of simple sugars in Biofuel and Food samples. The peak efficiencies produced by the Dionex CarboPac SA10-4?m columns produce 60 – 80% higher peak efficiencies than standard Dionex CarboPac SA10 columns, thus producing better resolution and easier peak identification and integration. The Dionex CarboPac SA10-4?m column can analyze six common sugars in Food samples in only 10 min, or eight common Biofuel mono- and disaccharides in less than 8 min.

This is the first in a series of Dionex CarboPac columns that use smaller resin particles. The smaller particles produce more efficient peaks and better resolution making analysis easier and more reliable.  The smaller particles also produce higher system back pressure (over 3000 psi) under standard operating conditions and therefore can only be run using Thermo Scientific? Dionex? HPIC? systems such as the Thermo Scientific Dionex ICS-5000+ HPIC system, which can operate up to 5000 psi.

The Dionex CarboPac SA10-4?m column should be used as a direct replacement for the Dionex CarboPac SA10 column only if an HPIC system is available

The polymeric Dionex CarboPac SA10-4?m column is packed with 4 ?m supermacroporous substrate, coated with the same strong anion-exchange layer of latex nano beads as the Dionex CarboPac SA10 column, which provides high capacity and rapid, high-resolution separations. The Dionex CarboPac SA10-4?m columns feature high reproducibility, and can withstand thousands of injection cycles under high pH conditions.

Thermo Scientific? Dionex? CarboPac? SA10-4?m Column for Monosaccharide and Disaccharide Analysis Specifications
Dimensions Dionex CarboPac SA10-4?m Analytical Column:
4 × 250 mm and 2 × 250 mm
Dionex CarboPac SA10-4?m Guard Column:
4 × 50 mm and 2 × 50 mm
Maximum operating pressure 5,000 psi (34.5 MPa)
Temperature range 4–60 °C
Typical operating conditions 4,000 psi at 1.5 mL/min (standard-bore column) or 0.38 mL/min (microbore column)
Recommended flow rate: 1.5 mL/min (standard-bore) or 0.38 mL/min (microbore)
Typical Eluents  Potassium hydroxide via Eluent Generation
Resin composition 4-?m diameter sumpermacroporous substrate (ethylvinylbenzene 55% crosslinked with divinylbenzene) agglomerated with 55-nm MicroBead difunctional quaternary ammonium ion (4.5% cross-linked).
Anion-exchange capacity

Approximay 290 ?eq/column (4 × 250 mm standard-bore column)

Approximay 73 ?eq/column (2 × 250 mm microbore column)

Column construction PEEK
Analytical Columns
Dionex CarboPac SA10-4?m Analytical Column (4 x 250 mm) 088233
Dionex CarboPac SA10-4?m Analytical Column (2 x 250 mm) 088235
Guard Columns
Dionex CarboPac SA10-4?m Guard Column (4 x 50 mm) 088234
Dionex CarboPac SA10-4?m Guard Column (2 x 50 mm) 088236